YiRadar · sensing systems for responsive environmentsSource-traceable product configurations

YR-DPA-DD-C1health care monitoring

Non-Contact Fall Monitoring Device

Non-contact millimeter-wave safety monitor for occupancy, multi-person fall detection, and trajectory tracking.

Source-traceable configurationFinal installation and compliance review required

Website publication review: Mr. Wang · 2026-08-24

YiRadar commercial visual for Non-Contact Fall Monitoring Device

Configuration snapshot

diameter
8 cm
weight
66 g
multi person resolution
≤0.5 m
monitoring radius
2 to 2.5 m

Key benefits

  • Occupancy monitoring
  • Multi-person fall monitoring
  • Trajectory tracking
  • Remote-upgrade and rollback capability described in source

Source-verified specifications

SpecificationSource-verified value
Diameter8 cm
Weight66 g
Multi-person resolution≤0.5 m
Monitoring radius2 to 2.5 m
Presence coverage≥16 m²
Fall-detection coverage≥12 m²
Maximum monitored people≥3
Fall-detection accuracy≥97%
False-alarm rate≤2%
Fall-response time3 to 180 seconds; configurable
InstallationCeiling mount; 2.1 to 3 m installation height
Power consumption≤2 W
Power inputDC 5 V / 2 A; Type-C
Operating temperature-15°C to 65°C
Connectivity4G or Wi-Fi optional

Typical applications

  • Elderly Care
  • Home Safety
  • Care Facility

Integration guidance

Select antenna placement, mounting method, power design, interface settings, and detection parameters according to the final product configuration. Confirm RF enclosure material, environmental conditions, and the target detection scenario with a YiRadar engineer before production deployment.

OEM / ODM

YiRadar supports review of firmware behavior, detection parameters, housing integration, connectors, and production packaging. Submit your target application, mounting geometry, power/interface requirements, and expected volume for technical evaluation.

FAQ

Can this product be used as a safety-certified system?

No safety, medical, regulatory, or protocol certification is claimed by this product page. Confirm the final product configuration, applicable regulations, and system-level validation requirements before deployment.

Can detection performance be changed?

Detection performance depends on installation, enclosure, firmware configuration, target behavior, and the surrounding environment. Discuss the deployment conditions with YiRadar before selecting or customizing a module.

Configuration note

This public configuration is a starting point for engineering discussion. Confirm final product configuration, project conditions, and applicable compliance obligations with YiRadar before deployment.